Description Détaillée
Overview The Ott CBS 500 is a versatile bubbler sensor for accurate water level measurement in surface water and groundwater applications. It uses the proven air-bubble principle, ensuring reliable performance even in dirty or dynamic conditions, as no electronics are submerged. The sensor delivers precise and stable measurements with high resolution and accuracy across measuring ranges up to 15 m and 30 m. Its low-maintenance design , including an integrated purge function, reduces servicing effort and supports long-term monitoring installations. Designed for modern monitoring networks, the CBS 500 offers flexible digital integration via SDI-12 and RS-485 (Modbus RTU) and can be easily connected to Ott, Sutron, and third-party dataloggers. It is optimized for remote and off-grid operation , supporting battery and solar-powered stations. Benefits Accurate and dependable results With a resolution of 1 mm and accuracy of up to ±3 mm in shallow ranges, the CBS 500 delivers precise and repeatable water level data across measuring ranges up to 15 m or 30 m. Built for remote and off-grid stations The CBS 500 operates on 12/24 V DC and supports battery or solar power. Intelligent pump control minimizes energy consumption while ensuring reliable operation, making it ideal for remote monitoring sites with limited power availability. Proven technology for reliable level data The Ott CBS 500 uses the proven air bubble principle to measure water level indirectly, making it ideal for surface water and groundwater applications where sensors are exposed to sediment, fouling, or aggressive conditions. No submerged electronics means stable measurements, even in dirty or dynamic water. One solution for surface water and groundwater By selecting the appropriate bubble chamber, the CBS 500 can be used in observation wells, rivers, channels, and reservoirs. Thus, the CBS 500 offers a single, versatile solution for multiple hydrological applications Low maintenance and long service life The CBS 500 features an integrated purge function that clears the measuring tube and bubble chamber of minor contamination using a high-volume air pulse. No air drying unit is required for most applications. This leads to reduced maintenance effort, fewer site visits, and lower total cost of ownership. Flexible integration into existing networks With native SDI-1, SDI-12 via RS-485 and Modbus RTU interfaces, the CBS 500 connects easily to OTT, Sutron, and third party dataloggers. Measurement units (metric or imperial) are factory preset and fully configurable. It enables seamless integration into new or existing stations without vendor lock-in.
Domaines d'application :
Surface Water Quantity, Groundwater
Avantages et Bénéfices de l'Instrument
Accurate and dependable results
Built for remote and off-grid stations
Proven technology for reliable level data
One solution for surface water and groundwater
Low maintenance and long service life
Flexible integration into existing networks
Caractéristiques et Attributs Techniques
Données constructeur certifiées par OTT HydroMet / Actimar.
| Measuring Range |
15m variant: 0 … 15 m or 0 … 1500 mbar (0 … 50 ft or 0 … 25 psi); 30m variant: 0 … 30 m or 0 … 3000 mbar (0 … 100 ft or 0 … 50 psi) |
| Resolution |
0.001 m · 0.1 cm · 1 mm · 0.1 mbar (0.0033 ft · 0.012 inch · 0.00142 psi) |
| Accuracy for measuring range 0 … 5 m |
±3 mm (±0.01 ft) |
| Accuracy for measuring range 5 … 15/30 m |
±0.065 % of measured value or ±5 mm, whichever value is lower (±0.065 % of measured value or ± 0.164 ft, whichever value is lower) |
| Measuring dynamics (max. level change) |
1 m/min (3.28 ft/min) |
| Units |
m · cm · mm · mbar · bar (ft · inch · psi · kPa) |
| Interfaces |
SDI-12, SDI-12 via RS-485 (V1.4), Modbus RTU via RS-485 |
| Power supply |
10 ... 30 VDC, typ. 12/24 VDC |
| Current consumption, query interval 1 min |
Typ. 320 mAh / day (max. 3 700 mAh / day) |
| Current consumption, query interval 15 min |
Typ. 25 mAh / day (max. 300 mAh / day) |
| Operating/display elements, "Pump" membrane button |
Call purge function; display error status using LED |
| Operating/display elements, "Status" LED |
Display operating state/error status |
| Dimensions |
165 mm x 205 mm x 115 mm |
| Weight |
1500 g |
| Housing material |
ABS |
| Protection class |
IP4X |
| Measuring tube internal diameter |
2 mm and 4 mm or 1/8" (depending on the device variant) |
| Measuring tube, max. length for 2 mm + ⅛ " internal diameter |
100 m (3,937 inches) |
| Measuring tube, max. length for 4 mm internal diameter |
75 m (246.06 feet) |
| Operating Temperature Range |
-20 ... +70 °C (-4 °F .... 158 °F) |
| Temperature range, storage |
-40 ... +80 °C (-40 °F to +176 °F) |
| Relative humidity |
10 ... 95 %; non-condensing |
| Measurement Range |
15 m (metric, standard tubing) |
Documentation, Manuels et Téléchargements
Fiches techniques, guides de démarrage et manuels complets à télécharger.
Brochure
Ott CBS 500 Datenblatt DE Data Sheets
Télécharger
Brochure
Ott CBS 500 Fiche Technique FR Data Sheets
Télécharger
Datasheet
Ott CBS 500 Ficha técnica ES Data Sheets
Télécharger
Datasheet
Ott CBS 500 Datasheet EN Data Sheets
Télécharger
Manual
Lufttrocknungseinheit OTT CBS 500 Anleitung DE Manuals
Télécharger
Manual
Unidad de secado de aire OTT CBS 500 Manuel de instrucciones ES Manuals
Télécharger
Manual
Ott CBS 500 Betriebsanleitung DE Manuals
Télécharger
Manual
Air drying unit OTT CBS 500 Instructions EN Manuals
Télécharger
Manual
Dessiccateur OTT CBS 500 Instructions FR Manuals
Télécharger
Manual
Ott CBS 500 Manual de instrucciones ES Manuals
Télécharger
Manual
Ott CBS 500 Manuel d'utilisation FR Manuals
Télécharger
Brochure
Building Flood Resilience - White Paper White Papers
Télécharger
Brochure
OTT Whitepaper - OTT Compact Bubbler Sensor (CBS) White Papers
Télécharger
Datasheet
OTT CBS - Lufteinperlsensor - Prospekt - DE Brochures
Télécharger
Brochure
Flood Management - Data to Save Lives Graphics
Télécharger
Brochure
Terms and Conditions of Sale (Europe)
Télécharger