03 Rue Chrifa Fayech, Riadh El Andalous, Ariana 2058
Lun - vendr : 08:00 - 16:30
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
SUTRON Water Flow & Discharge Réf : SDR-0001-1

SUTRON SDR Stage Discharge Recorder

Water Level Water Discharge

Overview SDR is a Logging Shaft Encoder used in surface water & groundwater applications. Front panel programmable, it holds over one year of data, & operates f...

Distribution et Garantie Officielle
Installation et Étalonnage Agréé
Support Technique et Pièces SAV

Description Détaillée

Overview SDR is a Logging Shaft Encoder used in surface water & groundwater applications. Front panel programmable, it holds over one year of data, & operates for over one year on alkaline batteries. SDR supports dual sensors to measure a second stage using an analog or SDI-12 sensor. It supports rating tables and incorporates standard flume and weir equations. Benefits Dual sensor Setup SDR to measure a second stage using an analog* or SDI-12 sensor. Averaging Stage can be computed by averaging multiple samples over a user-set period. Rating table Compute discharge using a rating table with up to 50 points.

Avantages et Bénéfices de l'Instrument

Dual sensor

Setup SDR to measure a second stage using an analog* or SDI-12 sensor.

Averaging

Stage can be computed by averaging multiple samples over a user-set period.

Rating table

Compute discharge using a rating table with up to 50 points.

Caractéristiques et Attributs Techniques

Données constructeur certifiées par OTT HydroMet / Actimar.

Parameters Measured Stage / Water Level, Internal Temperature, Battery
Dimensions (free text) 4.5 x 4 x 7 in (11.5 x 10.2 x 17.8 cm)
Power Consumption ˂3.5 mA @12 VDC
Interface SDI-12, RS-232
SD Card No
Control and Display Display Type: 2 x 20 LCD with backlight Keypad Type: 6 button
Operating temp range 1 -40 - +140 °F (-40 - +60 °C)
Shaft Encoder Yes
Data storage ˃ 300,000 readings
Protocol MODBUS Slave. SCP, SDI-12
Analogue inputs No
Resolution Shaft encoder has 400 count / revolution
Calculations Discharge using Parshall Flume, Broad Crested Weir equations, Dual Sensor, Rating Table or general purpose equation with user entered constants. Calculation of daily volume and daily average stage.
Power supply 5.5 - 16 VDC
Material enclosures NEMA 3, IP63 resists dripping water & spray
Measuring interval 15-minute (default) 1, 5, and 10-min user selectable
Programming Via front panel or SDR communicator program
Analog Output No

Documentation, Manuels et Téléchargements

Fiches techniques, guides de démarrage et manuels complets à télécharger.

Datasheet
Stage Discharge Recorder Datasheet Data Sheets
Télécharger
Manual
SDI-12 Shaft Encoder Accessories Manuals
Télécharger
Manual
Stage Discharge Recorder QuickStart Guide Manuals
Télécharger
Manual
SDR-9210 Integration Guide Manuals
Télécharger
Manual
Stage Discharge Recorder - Manual Manuals
Télécharger
Brochure
Stage Discharge Recorder Tender Specfications Engineering Tender
Télécharger
Quick Start Guide
SDR - Product Presentation Guides
Télécharger
Brochure
Terms & Conditions of Purchase
Télécharger
Brochure
Terms and Conditions of Sale (Europe)
Télécharger