03 Rue Chrifa Fayech, Riadh El Andalous, Ariana 2058
Lun - vendr : 08:00 - 16:30
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
OTT Water Level Réf : 6303900190-S-M-1

OTT PLS 500 Smart Pressure Level Sensor

Water Level Water Discharge Water Pressure Water Temperature Flood Monitoring Groundwater Surface Water Quantity

Overview Building on years of experience with the robust and accurate Ott PLS, the PLS 500 water level monitoring solution adds innovative metadata and internal...

Distribution et Garantie Officielle
Installation et Étalonnage Agréé
Support Technique et Pièces SAV

Description Détaillée

Overview Building on years of experience with the robust and accurate Ott PLS, the PLS 500 water level monitoring solution adds innovative metadata and internal sensors to remotely verify device performance providing peace of mind for long term deployment The Ott PLS 500 measures water level, depth to water, or pressure by means of an easy to maintain, ceramic pressure cell. This highly accurate sensor includes design features such as four internal compensations, stainless steel housing, and a rugged cable making it ideal for monitoring water level in a variety of applications. Common communication protocols (SDI-12 and Modbus RTU) allow for seamless integration with external data loggers. The accurate temperature measurements and built-in microcontroller compensate for environmental changes in water density. Built-in QA/QC and metadata along with reduced sensor drift allow you to have full confidence in your long-term data. Custom Cable All PLS 500s are manufactured with cables cut to the users specifications upon order. Please specify the length of cable (meters or feet) that you require with any quoted item. Benefits Automatic Compensations Automatically compensate for changes in atmospheric pressure with the vented probe. Reduce the amount of equipment needed in field by forgoing additional barometric pressure sensors and achieve better accuracy with a single compensated sensor. Internal Humidity Sensor The integrated internal humidity sensor outputs automatic status flags or direct humidity measurements to help you understand if condensation may have formed, impacting your pressure measurements. Data Processing Internally convert high frequency (4 Hz) measurements to calculations such as computed averages, minimum/maximum levels, and instantaneous values over user defined intervals, enabling greater information reporting and eliminating manual data post-processing/analysis. Rugged Design Ceramic pressure cell resistant to physical force and enclosure made of high-quality, saltwater resistant 904L stainless steel for use in coastal environments. The robust ceramic pressure cell offers industry-leading accuracy and does not deform over time like membrane technology, providing long-term measurement stability. Position Sensor Remotely monitor probe movement in the field with an internal inclinometer, enabling warnings if sensor position has changed due to in-stream events via automatic status flags or direct measurement. Discharge Calculations Automatically calculate discharge from either a user defined rating table or ISO 1100-2 exponential formula set-up via SDI-12 commands. Minimize the need for data post-processing by directly outputting discharge from a trusted level sensor.
Domaines d'application :

Flood Monitoring, Groundwater, Surface Water Quantity

Avantages et Bénéfices de l'Instrument

Automatic Compensations

Automatically compensate for changes in atmospheric pressure with the vented probe. Reduce the amount of equipment needed in field by forgoing additional barometric pressure sensors and achieve better accuracy with a single compensated sensor.

Internal Humidity Sensor

The integrated internal humidity sensor outputs automatic status flags or direct humidity measurements to help you understand if condensation may have formed, impacting your pressure measurements.

Data Processing

Internally convert high frequency (4 Hz) measurements to calculations such as computed averages, minimum/maximum levels, and instantaneous values over user defined intervals, enabling greater information reporting and eliminating manual data post-processing/analysis.

Rugged Design

Ceramic pressure cell resistant to physical force and enclosure made of high-quality, saltwater resistant 904L stainless steel for use in coastal environments. The robust ceramic pressure cell offers industry-leading accuracy and does not deform over time like membrane technology, providing long-term measurement stability.

Position Sensor

Remotely monitor probe movement in the field with an internal inclinometer, enabling warnings if sensor position has changed due to in-stream events via automatic status flags or direct measurement.

Discharge Calculations

Automatically calculate discharge from either a user defined rating table or ISO 1100-2 exponential formula set-up via SDI-12 commands. Minimize the need for data post-processing by directly outputting discharge from a trusted level sensor.

Caractéristiques et Attributs Techniques

Données constructeur certifiées par OTT HydroMet / Actimar.

Value Processing Average pressure or level over measurement interval
Protection class IP68
Power Consumption Sleep: 250 μA; typically 15 μA
Temperature range -20 °C (ice-free) ... +70 °C (-4 °F ... +158 °F)
Unit System Metric (pre-configured)
Power supply 5.5...28.8 V typically 12/24 V DC
Temperature resolution 0.01 °C (0.01 °F)
Level Accuracy Accuracy (linearity + hysteresis) For all measuring ranges: ± 0.05 % full scale Accuracy for 0 ... 10 m / 0... 1 bar variant (Meets USGS OSW): ±2 mm / 0 ... 5 m (-5 … +55 °C) ±3 mm / 0 ... 5 m (-20 … -5 °C; +55 … +70 °C) ±5 mm / 5 ... 10 m (-20 … +70 °C) 0.007 ft / 0 ... 17 ft (+23 … +131 °F) 0.010 ft / 0 ... 17 ft (-4 … +23 °F; +131 … +158 °F) 0.017 ft / 17 ... 33 ft (-4 … +158 °F)
Resolution 0.001 m / 0.1 cm / 0.00001 bar / 0.01 mbar (0.001 ft / 0.001 inch / 0.0001 psi)
Measurement Range 0 - 10 m (0 - 33 ft)
Temperature Accuracy ± 0.15 °C; Typ. ± 0.05 °C ( ± 0.07 °F; Typ. ± 0.03 °F)
Body Material Stainless steel 1.4539 (904L) resistant to sea water
Interface SDI-12 and RS485 (SDI-12 v1.4 and Modbus RTU)
Protocol SDI-12 (pre-configured)

Documentation, Manuels et Téléchargements

Fiches techniques, guides de démarrage et manuels complets à télécharger.

Certificate
OTT PLS 500 - FCC/ICES Suppliers Declaration of Conformity Certificates
Télécharger
Certificate
OTT PLS 500 Declaration of Conformity Certificates
Télécharger
Case Study
Flood Monitoring System in La Veta, Colorado - Case Study Case Studies
Télécharger
Brochure
OTT PLS 500 Data Sheet Data Sheets
Télécharger
Brochure
OTT PLS 500 - Fiche technique Data Sheets
Télécharger
Brochure
OTT PLS 500 - Ficha técnica Data Sheets
Télécharger
Brochure
Urban Flood Warning Station - Data Sheet Data Sheets
Télécharger
Brochure
OTT PLS 500 - Datenblatt Data Sheets
Télécharger
Brochure
OTT PLS 500 vs OTT PLS Graphics
Télécharger
Manual
OTT PLS 500 - Manuel d'utilisation Manuals
Télécharger
Manual
OTT PLS 500 - Manual de instrucciones Manuals
Télécharger
Manual
OTT PLS 500 User Manual Manuals
Télécharger
Manual
OTT PLS 500 - Bedienungsanleitung Manuals
Télécharger
Datasheet
OTT PLS 500 Sonda manométrica inteligente Brochures
Télécharger
Datasheet
OTT PLS 500 Intelligente Drucksonde Brochures
Télécharger
Datasheet
OTT PLS 500 - Sonde de pression intelligente Brochures
Télécharger
Datasheet
OTT PLS 500 Smart Pressure Level Sensor - Brochure Brochures
Télécharger
Brochure
Dam Safety & Monitoring - Application Note Application Notes
Télécharger
Quick Start Guide
OTT PLS500 vs OTT PLS Guides
Télécharger
Quick Start Guide
OTT PLS 500 Product Guide Guides
Télécharger
Brochure
Terms & Conditions of Purchase
Télécharger
Brochure
Terms and Conditions of Sale (Europe)
Télécharger